3-phase, 400V series (0.75 to 710kW) |
Item |
Specifications (0.75->11kW) |
Model |
FRN ### AQ1 (kW) |
0.75 |
1.5 |
2.2 |
4.0 |
5.5 |
7.5 |
11 |
Applicable standard motor (rated output) [kW]*1 |
0.75 |
1.5 |
2.2 |
4.0 |
5.5 |
7.5 |
11 |
Output ratings |
Rated capacity [kVA] *2 |
1.9 |
3.1 |
4.1 |
6.8 |
10 |
14 |
18 |
Voltage [V]*3 |
3-phase, 380 to 480V (with AVR function) |
Rated current [A] |
2.5 |
4.1 |
5.5 |
9.0 |
13.5 |
18.5 |
24.5 |
Overload current rating |
110%-1min (Overload tolerated interval: compliant with IEC 61800-2) |
Rated frequency [Hz] |
50, 60Hz |
Input Power Supply |
Main power supply (No. of phase, voltage, freguency) |
3-phase, 380 to 480V, 50/60Hz |
Control power supply auxiliary-input (No. of phase, voltage, freguency) |
Single phase, 380 to 480V, 50/60Hz |
Voltage, frequency variations |
Voltage: +10 to -15% (Unbalance rate between phases is within 2%) Frequency : +5 to -5% |
Rated input current [A] |
1.6 |
3.0 |
4.3 |
7.4 |
10.3 |
13.9 |
20.7 |
Required power supply capacity [kVA] |
1.2 |
2.1 |
3.0 |
5.2 |
7.2 |
9.7 |
15 |
Braking |
Braking torque [%]*5 |
20 |
DC braking |
Braking starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% |
EMC filter |
Built-in [Compliant with EMC standard (IEC/EN61800-3:2004)] |
DC reactor (DCR) |
Built-in (IEC/EN61000-3-2, IEC/EN61000-3-12) |
Compliant with Electrical Safety Standards |
UL508C, C22.2No.14, IEC/EN61800-5-1:2007 |
"#" Enclosure (IEC/EN60529) |
IP21/IP55 |
Cooling method |
Natural cooling |
Fan cooling |
Weight/Mass [kg] |
IP21/IP55 |
10 |
10 |
10 |
10 |
10 |
10 |
18 |
Item |
Specifications (15->55kW) |
Model |
FRN ### AQ1 (kW) |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
Applicable standard motor (rated output) [kW]*1 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
Output ratings |
Rated capacity [kVA] *2 |
24 |
29 |
34 |
45 |
57 |
69 |
85 |
Voltage [V]*3 |
3-phase, 380 to 480V (with AVR function) |
Rated current [A] |
32 |
39 |
45 |
60 |
75 |
91 |
112 |
Overload current rating |
110%-1min (Overload tolerated interval: compliant with IEC 61800-2) |
Rated frequency [Hz] |
50, 60Hz |
Input Power Supply |
Main power supply (No. of phase, voltage, freguency) |
3-phase, 380 to 480V, 50/60Hz |
Control power supply auxiliary-input (No. of phase, voltage, freguency) |
Single phase, 380 to 480V, 50/60Hz |
Voltage, frequency variations |
Voltage: +10 to -15% (Unbalance rate between phases is within 2%) Frequency : +5 to -5% |
Rated input current [A] |
27.9 |
34.5 |
41.1 |
55.7 |
69.4 |
83.1 |
102 |
Required power supply capacity [kVA] |
20 |
24 |
29 |
39 |
49 |
58 |
71 |
Braking |
Braking torque [%]*5 |
20 |
10 to 15 |
DC braking |
Braking starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% |
EMC filter |
Built-in [Compliant with EMC standard (IEC/EN61800-3:2004)] |
DC reactor (DCR) |
Built-in (IEC/EN61000-3-2, IEC/EN61000-3-12) |
Compliant with Electrical Safety Standards |
UL508C, C22.2No.14, IEC/EN61800-5-1:2007 |
"#" Enclosure (IEC/EN60529) |
IP21/IP55 |
Cooling method |
Fan cooling |
Weight/Mass [kg] |
IP21/IP55 |
18 |
18 |
18 |
23 |
23 |
TBD |
TBD |
Item |
Specifications (75->220kW) |
Model |
FRN ### AQ1 (kW) |
75 |
90 |
110 |
132 |
160 |
200 |
220 |
Applicable standard motor (rated output) [kW]*1 |
75 |
90 |
110 |
132 |
160 |
200 |
220 |
Output ratings |
Rated capacity [kVA] *2 |
114 |
134 |
160 |
192 |
231 |
287 |
316 |
Voltage [V]*3 |
3-phase, 380 to 480V (with AVR function ) |
Rated current [A] |
150 |
176 |
210 |
253 |
304 |
377 |
415 |
Overload current rating |
110%-1min (Overload tolerated interval: compliant with IEC 61800-2) |
Rated frequency [Hz] |
50, 60Hz |
Input Power Supply |
Main power supply (No. of phase, voltage, freguency) |
3-phase, 380 to 480V, 50/60Hz |
Control power supply auxiliary-input (No. of phase, voltage, freguency) |
Single phase, 380 to 480V, 50/60Hz |
Voltage, frequency variations |
Voltage: +10 to -15% (Unbalance rate between phases is within 2%)*4 Frequency : +5 to -5% |
Rated input current [A] |
136 |
162 |
201 |
238 |
286 |
357 |
390 |
Required power supply capacity [kVA] |
95 |
113 |
140 |
165 |
199 |
248 |
271 |
Braking |
Braking torque [%]*5 |
10 to 15 |
DC braking |
Braking starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% |
EMC filter |
Built-in [Compliant with EMC standard (IEC/EN61800-3:2004)] |
DC reactor (DCR) |
Built-in |
Standard accessory (IEC/EN61000-3-2, IEC/EN61000-3-12) |
Compliant with Electrical Safety Standards |
UL508C, C22.2No.14, IEC/EN61800-5-1:2007 |
"#" Enclosure (IEC/EN60529) |
IP21/IP55 |
IP00 |
Cooling method |
Fan cooling |
Weight/Mass [kg] |
IP21/IP55 |
TBD |
TBD |
|
|
|
|
|
IP00 |
|
|
62 |
64 |
94 |
98 |
129 |
Item |
Specifications (280->710kW) |
Model |
FRN ### AQ1 (kW) |
280 |
315 |
355 |
400 |
500 |
630 |
710 |
Applicable standard motor (rated output) [kW]*1 |
280 |
315 |
355 |
400 |
500 |
630 |
710 |
Output ratings |
Rated capacity [kVA] *2 |
396 |
445 |
495 |
563 |
731 |
891 |
1044 |
Voltage [V]*3 |
3-phase, 380 to 480V (with AVR function ) |
Rated current [A] |
520 |
585 |
650 |
740 |
960 |
1170 |
1370 |
Overload current rating |
110%-1min (Overload tolerated interval: compliant with IEC 61800-2) |
Rated frequency [Hz] |
50, 60Hz |
Input Power Supply |
Main power supply (No. of phase, voltage, freguency) |
3-phase, 380 to 480V, 50/60Hz |
Control power supply auxiliary-input (No. of phase, voltage, freguency) |
Single phase, 380 to 480V, 50/60Hz |
Voltage, frequency variations |
Voltage: +10 to -15% (Unbalance rate between phases is within 2%)*4 Frequency : +5 to -5% |
Rated input current [A] |
500 |
559 |
628 |
705 |
881 |
1115 |
1256 |
Required power supply capacity [kVA] |
347 |
388 |
436 |
489 |
611 |
773 |
871 |
Braking |
Braking torque [%]*5 |
10 to 15 |
DC braking |
Braking starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% |
EMC filter |
Built-in [Compliant with EMC standard (IEC/EN61800-3:2004)] |
DC reactor (DCR) |
Standard accessory (IEC/EN61000-3-2, IEC/EN61000-3-12) |
Compliant with Electrical Safety Standards |
UL508C, C22.2No.14, IEC/EN61800-5-1:2007 |
"#" Enclosure (IEC/EN60529) |
IP00 |
Cooling method |
Fan cooling |
Weight/Mass [kg] |
IP21/IP55 |
|
|
|
|
|
|
|
IP00 |
140 |
245 |
245 |
245 |
330 |
530 |
530 |