Three-phase 400 V (4 -> 45kW) |
Item |
Specifications |
Type FRN###LM1S *1 |
4.0 |
5.5 |
7.5 |
11 |
15 |
Nominal applied motor (kW) *2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
Output |
Rated capacity (kVA) *3 |
6.8 |
10.2 |
14 |
18 |
24 |
Rated voltage (V) *4 |
Three-phase 380 to 480 V, 50/60 Hz |
Rated current (A) *5 |
9.0 |
13.5 |
18.5 |
24.5 |
32.0 |
Overload capability A
(Permissible energization time) |
18.0 |
27.0 |
37.0 |
49.0 |
64.0 |
(3s) |
(10 s) |
(10 s) |
(10 s) |
(10 s) |
Rated frequency Hz |
50, 60 Hz |
Input |
Normal
powered |
Phases, voltage,
frequency |
Main power supply |
Three-phase, 380 to 480 V, 50/60 Hz |
Auxiliary control power input |
Single-phase, 200 to 480 V, 50/60 Hz |
Voltage/frequency variations |
Voltage: +10 to -15% (Voltage unbalance: 2% or less *8) Frequency: +5 to -5% |
Rated
current *6 A |
(with DCR) |
7.5 |
10.6 |
14.4 |
21.1 |
28.8 |
(without DCR) |
13 |
17.3 |
23.2 |
33 |
43.8 |
Required power supply capacity *7 |
5.2 |
7.4 |
10 |
15 |
20 |
Battery
powered |
Main power supply |
48 VDC or higher |
Auxiliary
control
power input |
Phases, voltage, frequency |
Single-phase 200 to 480 V, 50/60 Hz |
Voltage/ frequency variations |
Voltage: +10 to -15%, Frequency: +5 to -5% |
Running time s |
180 |
Braking |
Braking time s |
30 |
Duty cycle (%ED) % |
50 |
Allowable minimum resistance *9 Ω |
96 |
64 |
48 |
24 |
24 |
DC reactor (DCR) |
Option |
Applicable safety standards |
EN50178:1997 EN954-1 (planning) |
Enclosure (IEC60529) |
IP20 |
Cooling method |
Fan cooling |
Weight / Mass (kg) |
3.0 |
5.6 |
5.7 |
7.5 |
11.1 |
Three-phase 400 V (18->45KW) |
Item |
Specifications |
Type FRN###LM1S *1 |
18.5 |
22 |
30 |
37 |
45 |
Nominal applied motor (kW) *2 |
18.5 |
22 |
30 |
37 |
45 |
Output |
Rated capacity (kVA) *3 |
29 |
34 |
45 |
57 |
69 |
Rated voltage (V) *4 |
Three-phase 380 to 480 V, 50/60 Hz |
Rated current (A) *5 |
39.0 |
45.0 |
60 |
75 |
91 |
Overload capability A
(Permissible energization time) |
78.0 |
90.0 |
108 |
135 |
163 |
(10 s) |
(10 s) |
(5 s) |
(5s) |
(5s) |
Rated frequency Hz |
50, 60 Hz |
Input |
Normal
powered |
Phases, voltage,
frequency |
Main power supply |
Three-phase, 380 to 480 V, 50/60 Hz |
Auxiliary control power input |
Single-phase, 200 to 480 V, 50/60 Hz |
Single-phase, 380 to 480 V, 50/60 Hz*10 |
Voltage/frequency variations |
Voltage: +10 to -15% (Voltage unbalance: 2% or less *8) Frequency: +5 to -5% |
Rated
current *6 A |
(with DCR) |
35.5 |
42.2 |
57.0 |
68.5 |
83.2 |
(without DCR) |
52.3 |
60.6 |
77.9 |
94.3 |
114 |
Required power supply capacity *7 |
25 |
30 |
40 |
48 |
58 |
Battery
powered |
Main power supply |
48 VDC or higher |
Auxiliary
control
power input |
Phases, voltage, frequency |
Single-phase 200 to 480 V, 50/60 Hz |
Single-phase, 380 to 480 V, 50/60 Hz*10 |
Voltage/ frequency variations |
Voltage: +10 to -15%, Frequency: +5 to -5% |
Running time s |
180 |
Braking |
Braking time s |
30 |
Duty cycle (%ED) % |
50 |
Allowable minimum resistance *9 Ω |
16 |
16 |
10 |
10 |
8 |
DC reactor (DCR) |
Option |
Applicable safety standards |
EN50178:1997 EN954-1 (planning) |
Enclosure (IEC60529) |
IP20 |
IP00 |
Cooling method |
Fan cooling |
Weight / Mass (kg) |
11.2 |
11.7 |
24 |
33 |
34 |