Inverter FRENIC LIFT Series Specifications: 200VAC (5.5->22kW)
Fuji Electric Europe introduces the new frequency inverter for lifts, Frenic Lift.
Over the years Fuji Electric has collected a know-how of inverters for lift applications, this know-how has resulted in a new inverter developed especially for lift applications and the high standards this require.
Fuji Electric has with Frenic Lift already a large market share of the lift industry in Spain and this has helped to develop and improve the inverter, which is now available for the entire European lift market.
The inverter offers many possibilities and as all Fuji Electric products a very high quality. Frenic Lift is one of the best inverters currently on the market for lift applications.
Frenic Lift offer:
- Speed control accuracy: + 0.01%
- Rise time: 300 µs
- 200% of rated current for 10 s
- Product range:
4.0kW to 45kW (3 ph 400V supply)
5.5kW to 22kW (3 ph 200V supply)
2.2kW (1 ph 200V supply)
Three-phase 200VAC (5.5 -> 22kW) |
Item |
Specifications |
Type FRN###LM1S *1 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
Nominal applied motor (kW) *2 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
Output |
Rated capacity (kVA) *3 |
10.2 |
14 |
18 |
24 |
28 |
34 |
Rated voltage (V) *4 |
Three-phase 200 to 240 V, 50/60 Hz |
Rated current (A) *5 |
27 |
37 |
49 |
63 |
74 |
90 |
Overload capability A
(Permissible energization time) |
54.0 |
74.0 |
98.0 |
126 |
148 |
180 |
(10 s) |
(10 s) |
(10 s) |
(10 s) |
(10 s) |
(5 s) |
Rated frequency Hz |
50, 60 Hz |
Input |
Normal
powered |
Phases, voltage,
frequency |
Main power supply |
Three-phase, 200 to 240 V, 50/60 Hz |
Auxiliary control power input |
Single-phase, 200 to 240 V, 50/60 Hz |
Voltage/frequency variations |
Voltage: +10 to -15% (Voltage unbalance: 2% or less *8) Frequency: +5 to -5% |
Rated
current *6 A |
(with DCR) |
21.1 |
28.8 |
42.2 |
57.6 |
71.0 |
84.4 |
(without DCR) |
31.5 |
42.7 |
60.7 |
80.1 |
97.0 |
112 |
Required power supply capacity *7 |
7.4 |
10 |
15 |
20 |
25 |
30 |
Battery
powered |
Main power supply |
24 VDC or higher |
Auxiliary
control
power input |
Phases, voltage, frequency |
Single-phase 200 to 240 V, 50/60 Hz |
Voltage/ frequency variations |
Voltage: +10 to -15%, Frequency: +5 to -5% |
Running time (s) |
180 |
Braking |
Braking time s |
30 |
Duty cycle (%ED) % |
50 |
Allowable minimum resistance *9 Ω |
15 |
10 |
7.5 |
6 |
4 |
3.5 |
DC reactor (DCR) |
Option |
Applicable safety standards |
EN50178:1997 EN954-1 (planning) |
Enclosure (IEC60529) |
IP20 |
Cooling method |
Fan cooling |
Weight / Mass (kg) |
5.6 |
5.7 |
7.5 |
11.1 |
11.2 |
11.7 |
*1 A box () in the above table replaces C, E, A or J depending on the shipping destination.
A box () in the above table replaces A for the inverter without a CAN port
*2 Fuji 4-pole standard motor
*3 Rated capacity is calculated by assuming the output rated voltage as 220 V.
*4 Output voltage cannot exceed the power supply voltage.
*5 Assuming the carrier frequency: 10 kHz, ambient temperature: less than 40°C, RMS output current of the inverter:
80% of the rated output current.
*6 Calculated under conditions specified by Fuji Electric, which are the power source capacity: 500 kVA, input
impedance: 5%, power supply voltage: 200 VAC, and power source frequency: 50 Hz.
*7 Obtained when a DC reactor is used.
*8 Voltage unbalance (%) = (Max. voltage (V) − Min. voltage (V)) × 67 (IEC61800-3 (5, 2, 3)) / Three - phase average voltage (V)
*9 Permissible error range of the minimum resistance is +5 to -5%.