MR-J3-T Servo Amplifier Specifications: 100VAC
CC-Link compatible (with built-in positioning function)
By setting position and speed data in the point tables in the servo amplifier, positioning operation is possible with a start signal from a host controller. Setting position and speed data in the point table, and start and stop operation are possible via CC-Link communication. By using MR-J3-D01 extension
IO unit, point table selection and positioning operation with DI/O commands are enabled. (CC-Link communication is not available when using the MR-J3-D01.)
Servo amplifier model MR-J3- |
10T1 |
20T1 |
40T1 |
Output |
Rated voltage |
3-phase 170VAC |
Rated current (A) |
1.1 |
1.5 |
2.8 |
Main circuit power supply |
Voltage/frequency (Note 1, 2) |
1-phase 100 to 120VAC 50/60Hz |
Rated current (A) |
3.0 |
5.0 |
9.0 |
Permissible voltage fluctuation |
1-phase 85 to 132VAC |
Permissible frequency fluctuation |
±5% maximum |
Control circuit power supply |
Voltage/frequency |
1-phase 100 to 120VAC 50/60Hz |
Rated current (A) |
0.4 |
Permissible voltage fluctuation |
1-phase 85 to 132VAC |
Permissible frequency fluctuation |
±5% maximum |
Power consumption (W) |
30 |
Interface power supply |
24VDC ±10% (required current capacity: 0.15A (Note 7)) |
Tolerable regenerative power of regenerative resistor (W) (Note 3, 4) |
Built-in regenerative resistor |
— |
10 |
10 |
External regenerative resistor (Standard accessory) (Note 5, 6) |
— |
— |
— |
Control system |
Sine-wave PWM control/current control system |
Dynamic brake |
Built-in (Note 8, 11) |
Safety features |
Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servo motor overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage protection, overspeed protection, excess error protection |
Structure (IP rating) |
Natural-cooling open (IP00) |
Environment |
Ambient temperature (Note 9) |
0 to 55°C (32 to 131°F) (non freezing), storage: -20 to 65°C (-4 to 149°F) (non freezing) |
Ambient humidity |
90% RH maximum (non condensing), storage: 90% RH maximum (non condensing) |
Atmosphere |
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust |
Elevation |
1000m or less above sea level |
Vibration |
5.9m/s2 or less at 10 to 55Hz (directions of X, Y and Z axes) |
Mass (kg [lb]) |
0.8 (1.8) |
0.8 (1.8) |
1 (2.2) |
Notes:
1. Rated output and speed of a servo motor are applicable when the servo amplifier, combined with the servo motor, is operated within the specified power supply voltage and frequency.
Torque drops when the power supply voltage is below the specified value.
2. For torque characteristics when combined with a servo motor, refer to the section “Servo motor torque characteristics” in this catalog.
3. Optimal regenerative resistor varies for each system. Select the most suitable regenerative resistor by using the capacity selection software.
4. Refer to the section “Options ●Optional regeneration unit” in this catalog for the tolerable regenerative power (W).
5. Servo amplifiers without an enclosed regenerative resistor are also available. Refer to “Servo Amplifier Model Designation” in this catalog for details.
6. The value in ( ) is applicable when the external regenerative resistors, GRZG400-MΩ (standard accessory) are used with cooling fans (2 units of 92 ✕ 92mm, minimum air flow: 1.0m3/min). Note that change in parameter No. PA02 is required.
7. 0.15A is the value when all of the input/output points are used. The current capacity can be stepped down according to the number of input/output points in use. Refer to “MR-J3-MT SERVO AMPLIFIER INSTRUCTION MANUAL” for details.
8. Special specification servo amplifiers without a dynamic brake are also available: MR-J3-MT(1)-ED. When using the servo amplifier without a dynamic brake, the servo motor does not stop immediately at alarm occurrence or power failure. Take measures to ensure safety on the entire system.
9. MR-J3-350T or smaller servo amplifiers can be mounted closely. In this case, operate them at the ambient temperature of 0 to 45°C (32 to 113°F) or at 75% or less of the effective load ratio.
10. Special specification servo amplifiers for 1-phase 200 to 240VAC are also available: MR-J3-MT-U004. The permissible voltage fluctuation for MR-J3-MT-U004 is 1-phase 170 to 264VAC.
11. When using the built-in dynamic brake, refer to “MR-J3-MT SERVO AMPLIFIER INSTRUCTION MANUAL” for the permissible load to motor inertia moment ratio.
12. Use an optional external dynamic brake with the servo amplifier. Without the external dynamic brake, a servo motor does not stop immediately at emergency stop and falls in free-run status, causing an accident such as machine collision, etc. Take measures to ensure safety on the entire system.
Combinations of Servo Amplifier MR-J3-A/B/T with capacity 22kW or smaller and Servo Motor
MR-J3-A/B/T |
200V class |
400V class |
HF-KP |
HF-MP |
HF-SP |
HF-JP |
HC-LP |
HC-RP |
HC-UP |
HA-LP |
HF-SP |
HF-JP |
HA-LP |
10 |
053, 13 |
053, 13 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
20 |
23 |
23 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
40 |
43 |
43 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
60 |
— |
— |
51, 52 |
53 |
— |
52 |
— |
— |
— |
524 |
534 |
— |
— |
70 |
73 |
73 |
— |
73 |
— |
— |
— |
72 |
— |
— |
— |
— |
— |
100 |
— |
— |
81,102 |
103 |
53 (Note 1) |
102 |
— |
— |
— |
1024 |
734, 1034 |
534 (Note 1) |
— |
200 |
— |
— |
121, 201, 152, 202 |
153,203 |
73, 103 (Note 1) |
152 |
103, 153 |
152 |
— |
1524, 2024 |
1534, 2034 |
734, 1034 (Note 1) |
— |
350 |
— |
— |
301,352 |
353 |
153, 203 (Note 1) |
202 |
203 |
202 |
— |
3524 |
3534 |
1534, 2034 (Note 1) |
— |
500 |
— |
— |
421, 502 |
503 |
353 (Note 1) |
302 |
353, 503 |
352, 502 |
502 |
5024 |
5034 |
3534 (Note 1) |
— |
700 |
— |
— |
702 |
703 |
503 (Note 1) |
— |
— |
— |
601, 701M, 702 |
7024 |
7034 |
5034 (Note 1) |
6014, 701M4 |
11K |
— |
— |
— |
903, 11K1M (Note 2) |
— |
— |
— |
— |
801, 12K1, 11K1M, 11K2 |
— |
9034, 11K1M4 (Note 2) |
— |
8014, 12K14, 11K1M4, 11K24 |
15K |
— |
— |
— |
15K1M (Note 2) |
— |
— |
— |
— |
15K1, 15K1M, 15K2 |
— |
15K1M4 (Note 2) |
— |
15K14, 15K1M4, 15K24 |
22K |
— |
— |
— |
— |
— |
— |
— |
— |
20K1, 25K1, 22K1M, 22K2 |
— |
— |
— |
20K14, 22K1M4, 22K24 |
Notes:
1. Use this servo motor when increasing the maximum torque.
2. Use a dedicated servo amplifier MR-J3-MA(4)/B(4)/T(4)-LR/-LW for HF-JP11K1M(4) and HF-JP15K1M(4). These servo motors cannot be used with any other servo amplifiers without “-LR/-LW”.
*The drive unit and the converter unit conform to EN, UL and c-UL standards.