Item |
Specifications (22->110kW) |
Type (FRN###F1S-2A) |
22 |
30 |
37 |
45 |
55 |
75 |
90 |
110 |
Applicable motor rating [kW] (*1) |
22 |
30 |
37 |
45 |
55 |
75 |
90 |
110 |
Output
ratings |
Rated capacity [kVA] (*2) |
32 |
43 |
53 |
64 |
80 |
105 |
122 |
148 |
Rated voltage [V] (*3) |
Three-phase 200V to 240V (with AVR function) |
Rated current [A] (*4)(*10) |
85 (80) |
114 (107) |
140 (130) |
170 (156) |
211 (198) |
276 (270) |
322 (320) |
390 (384) |
Overload capability |
120% of rated current for 1min, |
Rated frequency [Hz] |
50, 60Hz |
Input
ratings |
Phases,
voltage,
frequency |
Main power supply |
Three-phase,
200 to 240V/50Hz |
Three-phase, 200 to 220V/50Hz
Three-phase, 200 to 230V/60Hz |
Auxiliary control
power input |
Single-phase,
200 to 240V/50Hz |
Single-phase, 200 to 220V/50Hz
Single-phase, 200 to 230V/60Hz |
Auxiliary fan
power input |
- |
Single-phase, 200 to 220V/50Hz
Single-phase, 200 to 230V/60Hz |
Voltage/frequency variations |
Voltage: +10 to -15% (Voltage unbalance (*8): 2% or less) Frequency: +5 to -5% |
Rated current [A] (*9) |
(with DCR) |
84.4 |
114 |
138 |
167 |
203 |
282 |
334 |
410 |
(without DCR) |
112 |
151 |
185 |
225 |
270 |
- |
- |
- |
Required power supply capacity [kVA] (*5) |
30 |
40 |
48 |
58 |
71 |
98 |
116 |
142 |
Braking |
Torque [%] |
20 |
10 to 15 |
DC injection braking |
Starting frequency: 0.1 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% of rated current |
Applicable safety standards |
UL508C, C22.2No.14, EN50178:1997 |
Enclosure (IEC60529) |
IP20, UL open type |
Cooling method |
Fan cooling |
Weight / Mass [kg] |
9.7 |
11.5 |
23 |
33 |
34 |
41 |
75 |
120 |